Comparison table of the relationship between valve size and medium velocity

Column:Technical article Time:2019-06-22
It is well known that the flow rate and velocity of the valve mainly depends on the size of the valve, but also with the valve structure type of the resistance to the medium...

It is well known that the flow rate and flow rate of the valve mainly depends on the size of the valve, and the valve structure type of the resistance to the medium, at the same time with the pressure of the valve, temperature and the concentration of the medium and other factors have a certain internal relationship.Valve flow area and flow velocity, flow rate has a direct relationship, and flow rate and flow are interdependent two quantities.When the flow rate is constant, the flow rate is large, the flow area can be smaller;Small velocity, the flow area can be larger.On the contrary, the flow area is large and the velocity is small.The runner area is small and the velocity is high.

 

1, the flow rate of the medium is large, the valve diameter can be small, but the resistance loss is large, the valve is easy to damage.High flow rate, the flammable and explosive media will produce electrostatic effect, resulting in danger;The flow rate is too small, inefficient, and uneconomical.For high viscosity and explosive medium, should be a small flow rate.The flow rate of oil and liquid with high viscosity is selected according to the viscosity, generally 0.1 ~ 2m/s.

2. Generally speaking, the flow rate is known and the flow rate can be determined by experience.Nominal size of valve can be calculated by flow rate and flow rate.

3, the valve size is the same, its structure is different, fluid resistance is not the same.Under the same conditions, the greater the resistance coefficient of the valve, the more fluid flow through the valve velocity, flow rate drop;The smaller the valve resistance coefficient is, the less the flow rate and flow rate decreases through the valve.

 

Common flow rates of various media are shown in the following table:

Fluid nameConditions of use
Velocity(m/s)
Saturated steam
DN>200
DN=200~100
DN<100
30~40
25~35
15~30
Superheated steam
DN>200
DN=200~100
DN<100
40~60
30~50
20~40
Low pressure steamρ<1.0(Absolute pressure)15~20
Medium pressure steamΡ=1.0~4.0(Absolute pressure)20~40
High pressure steamΡ=4.0~12.0(Absolute pressure)40~60

Compressed gas
Vacuum
Ρ≤0.3(Gage pressure)
Ρ=0.3~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
Ρ=3.0~30.0(Gage pressure)
5~10
8~12
10~20
10~15
8~12
3~6
0.5~3
oxygen
Ρ=0~0.05(Gage pressure)
Ρ=0.05~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
5~10
7~8
4~6
4~5
3~4
Gas 2.5~15
Semi water gasΡ=0.1~0.15(Gage pressure)10~15
Natural gas 30
NitrogenΡ=5~10(Absolute pressure)15~25

ammonia
vacuum
Ρ<0.3(Gage pressure)
Ρ<0.6(Gage pressure)
Ρ≤2(Gage pressure)
15~25
8~15
10~20
3~8
Acetylene water 
30
5~6
Acetylene water
ρ<0.01(Gage pressure)
ρ<0.15(Gage pressure)
ρ<2.5(Gage pressure)
3~4
4~8
5
chlorine
Gas
liquid
10~25
1.6
氯化氫
氣體
液體
20
1.5
Liquid ammonia
Vacuum
Ρ≤0.6(Gage pressure)
Ρ≤2.0(Gage pressure)
0.05~0.3
0.3~0.8
0.8~1.5

Sodium hydroxide
Concentration 0~30%
Concentration 30%~505
Concentration 50%~73%
2
1.5
1.2
Sulfuric acid
Concentration 88%~93%
Concentration 93%~100%
1.2
1.2
HCl 1.5
Water has a similar viscosity to liquids
Ρ=0.1~0.3(Gage pressure)
Ρ≤1.0(Gage pressure)
Ρ≤8.0Gage pressure)
Ρ≤20~30(Gage pressure)
Heat network circulating water, cooling water
0.5~2
0.5~3
2~3
2~3.5
0.3~1
Water has a similar viscosity to liquidsPressure backwater0.5~2
Water has a similar viscosity to liquidsNo pressure backwater0.5~1.2

Tap water
DirectorΡ=0.3(Gage pressure)
BranchΡ=0.3(Gage pressure)
1.5~3.5
1~1.5
Boiler feed water >3
Steam condensate 0.5~1.5
CondensateGravity0.2~0.5
Hot water 2
Sea water, slightly alkaline water
Ρ<0.6(Gage pressure)
1.5~2.5

Note: the unit of DN value is mm;Ρ value unit is: MPa.


Examples:
 

The resistance coefficient of gate valve is small, only within the range of 0.1 ~ 1.5.Gate valve with large diameter, the resistance coefficient is 0.2 ~ 0.5;Shrinkage gate valve resistance coefficient is larger.

 

The resistance coefficient of globe valves is much larger than that of gate valves, generally between 4 and 7.Y-type globe valve (direct flow) has a small resistance coefficient between 1.5 and 2.Forged steel globe valve resistance coefficient is large, even up to 8.

 

The resistance coefficient of the check valve depends on the structure: swing check valve is usually about 0.8 ~ 2, in which the multi-lobe swing check valve has a larger resistance coefficient;Lift check valve resistance coefficient, up to 12.

 

Plug valve resistance coefficient is small, usually about 0.4 ~ 1.2.

 

The resistance coefficient of diaphragm valve is generally around 2.3.

 

Butterfly valve resistance coefficient is small, generally within 0.5.

 

Ball valve resistance coefficient is small, generally around 0.1.

 

Remark: the resistance coefficient of the valve is the value when the valve is fully open.

 

The selection of valve size should take into account the machining accuracy and dimension deviation of the valve, as well as other factors.Valve size should be adequate, generally 15%.In practice, the size of the valve varies with the size of the process line.


Knowledge: valve size and inch comparison table valve size (DN) and diameter comparison table


主站蜘蛛池模板: 欧美另类videosbestsex久久 | 国产亚洲欧美在线观看的 | 国产精品1024永久免费视频 | 欧美精品日日鲁夜夜 | 激情综合网五月天 | 亚洲精品久久久久久久网站 | 国产亚洲sss在线观看 | 国产原创中文视频 | 在线亚洲+欧美+日本专区 | 182tv免费福利夜在线观看 | 精品一区二区久久久久久久网站 | 97狠狠干| 国产精品久久久久三级 | 亚洲精品综合一区二区三区在线 | 涩涩999 | 欧美日韩亚洲一区二区三区在线观看 | 亚洲欧美中文字幕在线网站 | a级日本高清免费看 | 在线欧美不卡 | 国产精品久久久久久久网站 | 一色桃子中文字幕 | 四虎影永久在线观看网址 | 色综合久久综合网欧美综合网 | 国内精品欧美久久精品 | 四虎影视永久在线精品免费 | 2021国产成人精品国产 | 你懂的福利视频 | 天天操夜夜艹 | 国产在热线精品视频国产一二 | 欧美成人高清免费大片观看 | 日本激情片在线观看 | 草草草影院 | 国产精品久久久久久久久久久威 | 天堂中文在线资源 | 狼人 成人 综合 亚洲 | 久久久国产99久久国产一 | 大桥未久一区二区 | 国产99视频精品免费视频免里 | 国产福利在线观看视频 | 天天爱天天操天天射 | 19国产精品麻豆免费观看 |